Inverter SOLAR EDGE SE100K – RW00IBNM4 + 3 auxiliary units SESUK- RWR0INNN4
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 9 |
AFCI | Yes |
Warranty | |
Wi-Fi | Optional |
Ethernet | Yes |
RS485 | Yes |
GSM | Optional |
SPD Type II | |
Weight | 114,52 kg |
CN | 85044086 |
Gross
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 9 |
AFCI | Yes |
Warranty | |
Wi-Fi | Optional |
Ethernet | Yes |
RS485 | Yes |
GSM | Optional |
SPD Type II | |
Weight | 114,52 kg |
CN | 85044086 |
SolarEdge Three-Phase Inverters with Synergy Technology (Europe)
SolarEdge three-phase inverters with synergy technology (models SE50K, SE66.6K, SE90K, SE100K, SE120K) are advanced solutions for large photovoltaic installations, designed for quick installation and maximum efficiency. With a modular design that includes 2 or 3 synergy units and one synergy management device, installation is straightforward and can be completed by two people. These inverters offer a long warranty period (12-20 years) and a range of built-in safety and monitoring features.
Key Features of SolarEdge Three-Phase Inverters with Synergy Technology:
- Quick installation and commissioning: A specialized preliminary handover process allows for automatic validation of components and wiring before connecting to the grid, and the lightweight, modular design simplifies assembly.
- High reliability and easy operation: Independent operation of each synergy unit extends the system’s uptime and simplifies maintenance.
- Advanced safety: Built-in temperature sensors detect wiring failures, integrated arc fault protection, optional rapid shutdown, and monitored, replaceable surge protections (SPD DC type 2, optionally AC type 2).
- Maximum system efficiency: Built-in capability to mitigate potential-induced degradation (PID) and a maximum inverter efficiency of 98.3%.
- Comprehensive monitoring: Integrated module-level monitoring with communication via Ethernet or cellular network (optional Wi-Fi), providing complete visibility into system performance.
- Wide power range: Available models with rated AC output power from 50 kW to 120 kW, suitable for large commercial and industrial projects.
Who is this a good choice for?
SolarEdge three-phase inverters with synergy technology are an ideal solution for large photovoltaic installations in the commercial and industrial sectors in the European market. Their modular construction, advanced safety features, high efficiency, and comprehensive monitoring capabilities make them an excellent choice for investors and developers looking for reliable, easy-to-install and operate, and cost-effective solutions. The long warranty period further confirms their high quality and durability.
Parameter | SE50K(1) | SE66.6K | SE90K | SE100K | SE120K |
---|---|---|---|---|---|
OUTPUT | SEXXK-RWX0IXXXX | SEXXK-RWX0IXXXX | SEXXK-RWX0IXXXX | SEXXK-RWX0IXXXX | SExxK-xxx8lxxxx |
Nominal active output power AC (W) | 50000(2) | 66600 | 90000 | 100000 | 120000 |
Maximum apparent output power AC (VA) | 50000(2) | 66600 | 90000 | 100000 | 120000 |
Output voltage AC – phase-phase/phase-neutral (nominal) (Vac) | 380/220; 400/230 | 380/220; 400/230 | 380/220; 400/230 | 380/220; 400/230 | 480/277 |
Output voltage AC – phase-phase/phase-neutral range (Vac) | 304-437/176-253; 320-460/184-264.5 | 304-437/176-253; 320-460/184-264.5 | 304-437/176-253; 320-460/184-264.5 | 304-437/176-253; 320-460/184-264.5 | 432-529 / 249-305 |
AC frequency (Hz) | 50/60 ± 5% | 50/60 ± 5% | 50/60 ± 5% | 50/60 ± 5% | 50/60 ± 5% |
Maximum continuous output current (per phase) (Aac) | 72.5 | 96.5 | 130.5 | 145 | 145 |
AC output line connections | 3W + PE, 4W + PE | 3W + PE, 4W + PE | 3W + PE, 4W + PE | 3W + PE, 4W + PE | 3W + PE, 4W + PE |
Supported networks | WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT | WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT | WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT | WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT | WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT |
Maximum differential current(3) (mA) | 200 | 200 | 300 | 300 | 300 |
Network monitoring, islanding protection, configurable power factor, configurable threshold values depending on the country | Yes | Yes | Yes | Yes | Yes |
Total harmonic distortion (%) | ≤ 3 | ≤ 3 | ≤ 3 | ≤ 3 | ≤ 3 |
Power factor range | +/- from 0.8 to 1 | +/- from 0.8 to 1 | +/- from 0.8 to 1 | +/- from 0.8 to 1 | +/- from 0.8 to 1 |
INPUT | |||||
Maximum DC power (STC module) inverter / synergy unit (W) | 75000 / 37500 | 100000 / 50000 | 135000 / 45000 | 150000 / 50000 | 180000 / 60000 |
Transformerless, ungrounded | Yes | Yes | Yes | Yes | Yes |
Maximum input voltage DC+ to DC- (VDC) | 1000 | 1000 | 1000 | 1000 | 850 |
Nominal input voltage DC+ to DC- (VDC) | 750 | 750 | 750 | 750 | 750 |
Maximum input current (ADC) | 2 x 36.25 | 2 x 48.25 | 3 x 43.5 | 3 x 48.25 | 3 x 48.25 |
Reverse polarity protection | Yes | Yes | Yes | Yes | Yes |
Ground fault detection | Sensitivity 167 kΩ per synergy unit(4) | Sensitivity 167 kΩ per synergy unit(4) | Sensitivity 167 kΩ per synergy unit(4) | Sensitivity 167 kΩ per synergy unit(4) | Sensitivity 167 kΩ per synergy unit(4) |
Maximum inverter efficiency (%) | 98.3 | 98.3 | 98.3 | 98.3 | 98.1 |
European efficiency (weighted) (%) | 98 | 98 | 98 | 98 | 98 |
Night power consumption (W) | < 8 | < 8 | < 12 | < 12 | < 12 |
ADDITIONAL FEATURES | |||||
Supported communication interfaces(5) | 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) | 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) | 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) | 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) | 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) |
Smart energy management | Export limitation | Export limitation | Export limitation | Export limitation | Export limitation |
Inverter startup | Mobile application SetApp using built-in Wi-Fi access point for local connection | Mobile application SetApp using built-in Wi-Fi access point for local connection | Mobile application SetApp using built-in Wi-Fi access point for local connection | Mobile application SetApp using built-in Wi-Fi access point for local connection | Mobile application SetApp using built-in Wi-Fi access point for local connection |
Arc interference protection | Built-in, user configurable (according to UL1699B) | Built-in, user configurable (according to UL1699B) | Built-in, user configurable (according to UL1699B) | Built-in, user configurable (according to UL1699B) | Built-in, user configurable (according to UL1699B) |
Rapid shutdown | Optional (automatic upon disconnection from AC grid) | Optional (automatic upon disconnection from AC grid) | Optional (automatic upon disconnection from AC grid) | Optional (automatic upon disconnection from AC grid) | Optional (automatic upon disconnection from AC grid) |
PID controller | Night hours, built-in | Night hours, built-in | Night hours, built-in | Night hours, built-in | Night hours, built-in |
RS485 surge protection (ports 1+2) | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated |
DC surge protection | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated | Type II, field-replaceable, integrated |
AC surge protection | Type II, field-replaceable, optional | Type II, field-replaceable, optional | Type II, field-replaceable, optional | Type II, field-replaceable, optional | Type II, field-replaceable, optional |
DC fuses (single-pole) | 25 A, optional | 25 A, optional | 25 A, optional | 25 A, optional | 25 A, optional |
DC disconnect switch | Optional | Optional | Optional | Optional | Optional |
COMPLIANCE WITH STANDARDS | |||||
Safety | IEC-62109-1, IEC-62109-2, AS3100 | IEC-62109-1, IEC-62109-2, AS3100 | IEC-62109-1, IEC-62109-2, AS3100 | IEC-62109-1, IEC-62109-2, AS3100 | IEC-62109-1, IEC-62109-2, AS3100 |
Grid connection standards(6) | EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 | EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 | EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 | EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 | EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 |
EMC | IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 | IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 |
RoHS | Yes | Yes | Yes | Yes | Yes |
INSTALLATION PARAMETERS | |||||
Number of synergy units per inverter | 2 | 2 | 3 | 3 | 3 |
Cross-section and outer diameter of AC wire: line/PE (aluminum or copper) (mm²/mm) | Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm | Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm | Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm | Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm | Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm |
DC input: inverter/synergy unit(7)(8) | 8/4 pairs MC4 | 8/4 pairs MC4 | Grommet, 2 pairs/1 pair, cross-section up to 50 mm², aluminum or copper, outer diameter of wire 12-20 mm | Grommet, 2 pairs/1 pair, cross-section up to 50 mm², aluminum or copper, outer diameter of wire 12-20 mm | 12/4 pairs MC4, Grommet, 3 pairs/1 pair, cross-section up to 50 mm² aluminum or copper, outer diameter of wire 12-20 mm |
Dimensions (h x w x d) (mm) – Synergy unit | 558 x 328 x 273 | 558 x 328 x 273 | 558 x 328 x 273 | 558 x 328 x 273 | 558 x 328 x 273 |
Dimensions (h x w x d) (mm) – Synergy management device | 360 x 560 x 295 | 360 x 560 x 295 | 360 x 560 x 295 | 360 x 560 x 295 | 360 x 560 x 295 |
Weight (kg) – Synergy unit | 32 | 32 | 32 | 32 | 32 |
Weight (kg) – Synergy management device | 18 | 18 | 18 | 18 | 18 |
Operating temperature range (°C) | from -40 to +60(9) | from -40 to +60(9) | from -40 to +60(9) | from -40 to +60(9) | from -40 to +60(9) |
Cooling | Fan (replaceable) | Fan (replaceable) | Fan (replaceable) | Fan (replaceable) | Fan (replaceable) |
Noise emission (dBA) | < 67 | < 67 | < 67 | < 67 | < 67 |
Degree of protection | IP65 – outdoors and indoors | IP65 – outdoors and indoors | IP65 – outdoors and indoors | IP65 – outdoors and indoors | IP65 – outdoors and indoors |
Mounting | Included bracket | Included bracket | Included bracket | Included bracket | Included bracket |
(1) Option available in some countries. For more information: https://www.solaredge.com/sites/default/files/se_inverters_supported_countries.pdf
(2) 49990 in the United Kingdom
(3) If an external RCD is required, its tripping value must be ≥ 200 mA for SE50K/SE66.6K; ≥ 300 mA for SE90K, SE100K
(4) If allowed by local regulations
(5) For specifications regarding additional communication options, please visit https://www.solaredge.com/products/communication or the Resource Library at: https://www.solaredge.com/downloads# to download the relevant datasheet
(6) All standards and certifications are available for download in the “Certificates” section of the Resource Library: https://www.solaredge.com/downloads#/
(7) DC input is available with MC4 connectors or grommets under the inverter part number. For more information, please contact SolarEdge
(8) Only MC4 connectors manufactured by Staubli are approved for use
(9) Power derating – for specifications, see https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf