Inverter SOLAR EDGE SE100K – RW00IBNM4 + 3 auxiliary units SESUK- RWR0INNN4

SKU: F240M02 EAN: 2010000031537
Manufacturer

Rated power

Power supply

Hybrid device

MPPT

9

AFCI

Yes

Warranty

Wi-Fi

Optional

Ethernet

Yes

RS485

Yes

GSM

Optional

SPD Type II

Weight 114,52 kg
CN 85044086
Price 4 641,50 
Gross

4 641,50 
Gross

In stock:

9 set
Login to place an order

4 641,50 
Gross

In stock:

9 set
Login to place an order

Product details

Manufacturer

Rated power

Power supply

Hybrid device

MPPT

9

AFCI

Yes

Warranty

Wi-Fi

Optional

Ethernet

Yes

RS485

Yes

GSM

Optional

SPD Type II

Weight 114,52 kg
CN 85044086

SolarEdge Three-Phase Inverters with Synergy Technology (Europe)

SolarEdge three-phase inverters with synergy technology (models SE50K, SE66.6K, SE90K, SE100K, SE120K) are advanced solutions for large photovoltaic installations, designed for quick installation and maximum efficiency. With a modular design that includes 2 or 3 synergy units and one synergy management device, installation is straightforward and can be completed by two people. These inverters offer a long warranty period (12-20 years) and a range of built-in safety and monitoring features.

Key Features of SolarEdge Three-Phase Inverters with Synergy Technology:

  • Quick installation and commissioning: A specialized preliminary handover process allows for automatic validation of components and wiring before connecting to the grid, and the lightweight, modular design simplifies assembly.
  • High reliability and easy operation: Independent operation of each synergy unit extends the system’s uptime and simplifies maintenance.
  • Advanced safety: Built-in temperature sensors detect wiring failures, integrated arc fault protection, optional rapid shutdown, and monitored, replaceable surge protections (SPD DC type 2, optionally AC type 2).
  • Maximum system efficiency: Built-in capability to mitigate potential-induced degradation (PID) and a maximum inverter efficiency of 98.3%.
  • Comprehensive monitoring: Integrated module-level monitoring with communication via Ethernet or cellular network (optional Wi-Fi), providing complete visibility into system performance.
  • Wide power range: Available models with rated AC output power from 50 kW to 120 kW, suitable for large commercial and industrial projects.

Who is this a good choice for?

SolarEdge three-phase inverters with synergy technology are an ideal solution for large photovoltaic installations in the commercial and industrial sectors in the European market. Their modular construction, advanced safety features, high efficiency, and comprehensive monitoring capabilities make them an excellent choice for investors and developers looking for reliable, easy-to-install and operate, and cost-effective solutions. The long warranty period further confirms their high quality and durability.

 

Parameter SE50K(1) SE66.6K SE90K SE100K SE120K
OUTPUT SEXXK-RWX0IXXXX SEXXK-RWX0IXXXX SEXXK-RWX0IXXXX SEXXK-RWX0IXXXX SExxK-xxx8lxxxx
Nominal active output power AC (W) 50000(2) 66600 90000 100000 120000
Maximum apparent output power AC (VA) 50000(2) 66600 90000 100000 120000
Output voltage AC – phase-phase/phase-neutral (nominal) (Vac) 380/220; 400/230 380/220; 400/230 380/220; 400/230 380/220; 400/230 480/277
Output voltage AC – phase-phase/phase-neutral range (Vac) 304-437/176-253; 320-460/184-264.5 304-437/176-253; 320-460/184-264.5 304-437/176-253; 320-460/184-264.5 304-437/176-253; 320-460/184-264.5 432-529 / 249-305
AC frequency (Hz) 50/60 ± 5% 50/60 ± 5% 50/60 ± 5% 50/60 ± 5% 50/60 ± 5%
Maximum continuous output current (per phase) (Aac) 72.5 96.5 130.5 145 145
AC output line connections 3W + PE, 4W + PE 3W + PE, 4W + PE 3W + PE, 4W + PE 3W + PE, 4W + PE 3W + PE, 4W + PE
Supported networks WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT WYE: TN-C, TN-S, TN-C-S, TT, IT; Delta: IT
Maximum differential current(3) (mA) 200 200 300 300 300
Network monitoring, islanding protection, configurable power factor, configurable threshold values depending on the country Yes Yes Yes Yes Yes
Total harmonic distortion (%) ≤ 3 ≤ 3 ≤ 3 ≤ 3 ≤ 3
Power factor range +/- from 0.8 to 1 +/- from 0.8 to 1 +/- from 0.8 to 1 +/- from 0.8 to 1 +/- from 0.8 to 1
INPUT
Maximum DC power (STC module) inverter / synergy unit (W) 75000 / 37500 100000 / 50000 135000 / 45000 150000 / 50000 180000 / 60000
Transformerless, ungrounded Yes Yes Yes Yes Yes
Maximum input voltage DC+ to DC- (VDC) 1000 1000 1000 1000 850
Nominal input voltage DC+ to DC- (VDC) 750 750 750 750 750
Maximum input current (ADC) 2 x 36.25 2 x 48.25 3 x 43.5 3 x 48.25 3 x 48.25
Reverse polarity protection Yes Yes Yes Yes Yes
Ground fault detection Sensitivity 167 kΩ per synergy unit(4) Sensitivity 167 kΩ per synergy unit(4) Sensitivity 167 kΩ per synergy unit(4) Sensitivity 167 kΩ per synergy unit(4) Sensitivity 167 kΩ per synergy unit(4)
Maximum inverter efficiency (%) 98.3 98.3 98.3 98.3 98.1
European efficiency (weighted) (%) 98 98 98 98 98
Night power consumption (W) < 8 < 8 < 12 < 12 < 12
ADDITIONAL FEATURES
Supported communication interfaces(5) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional) 2 x RS485, Ethernet, Wi-Fi (optional), cellular network (optional)
Smart energy management Export limitation Export limitation Export limitation Export limitation Export limitation
Inverter startup Mobile application SetApp using built-in Wi-Fi access point for local connection Mobile application SetApp using built-in Wi-Fi access point for local connection Mobile application SetApp using built-in Wi-Fi access point for local connection Mobile application SetApp using built-in Wi-Fi access point for local connection Mobile application SetApp using built-in Wi-Fi access point for local connection
Arc interference protection Built-in, user configurable (according to UL1699B) Built-in, user configurable (according to UL1699B) Built-in, user configurable (according to UL1699B) Built-in, user configurable (according to UL1699B) Built-in, user configurable (according to UL1699B)
Rapid shutdown Optional (automatic upon disconnection from AC grid) Optional (automatic upon disconnection from AC grid) Optional (automatic upon disconnection from AC grid) Optional (automatic upon disconnection from AC grid) Optional (automatic upon disconnection from AC grid)
PID controller Night hours, built-in Night hours, built-in Night hours, built-in Night hours, built-in Night hours, built-in
RS485 surge protection (ports 1+2) Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated
DC surge protection Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated Type II, field-replaceable, integrated
AC surge protection Type II, field-replaceable, optional Type II, field-replaceable, optional Type II, field-replaceable, optional Type II, field-replaceable, optional Type II, field-replaceable, optional
DC fuses (single-pole) 25 A, optional 25 A, optional 25 A, optional 25 A, optional 25 A, optional
DC disconnect switch Optional Optional Optional Optional Optional
COMPLIANCE WITH STANDARDS
Safety IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100 IEC-62109-1, IEC-62109-2, AS3100
Grid connection standards(6) EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019 EN50549-1, EN50549-2, VDE-AR-N 4105, VDE-AR-N 4110, VDE V 0126-1-1, CEI 0-21, CEI 0-16, TOR Generator Type A+B, G99 Type A+B, G99 (NI) Type A, VFR 2019
EMC IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12 IEC61000-6-2, IEC61000-6-3 class A, IEC61000-3-11, IEC61000-3-12
RoHS Yes Yes Yes Yes Yes
INSTALLATION PARAMETERS
Number of synergy units per inverter 2 2 3 3 3
Cross-section and outer diameter of AC wire: line/PE (aluminum or copper) (mm²/mm) Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm Cross-section up to 120 / 70 mm²; outer diameter 30-50 / 12-20 mm
DC input: inverter/synergy unit(7)(8) 8/4 pairs MC4 8/4 pairs MC4 Grommet, 2 pairs/1 pair, cross-section up to 50 mm², aluminum or copper, outer diameter of wire 12-20 mm Grommet, 2 pairs/1 pair, cross-section up to 50 mm², aluminum or copper, outer diameter of wire 12-20 mm 12/4 pairs MC4, Grommet, 3 pairs/1 pair, cross-section up to 50 mm² aluminum or copper, outer diameter of wire 12-20 mm
Dimensions (h x w x d) (mm) – Synergy unit 558 x 328 x 273 558 x 328 x 273 558 x 328 x 273 558 x 328 x 273 558 x 328 x 273
Dimensions (h x w x d) (mm) – Synergy management device 360 x 560 x 295 360 x 560 x 295 360 x 560 x 295 360 x 560 x 295 360 x 560 x 295
Weight (kg) – Synergy unit 32 32 32 32 32
Weight (kg) – Synergy management device 18 18 18 18 18
Operating temperature range (°C) from -40 to +60(9) from -40 to +60(9) from -40 to +60(9) from -40 to +60(9) from -40 to +60(9)
Cooling Fan (replaceable) Fan (replaceable) Fan (replaceable) Fan (replaceable) Fan (replaceable)
Noise emission (dBA) < 67 < 67 < 67 < 67 < 67
Degree of protection IP65 – outdoors and indoors IP65 – outdoors and indoors IP65 – outdoors and indoors IP65 – outdoors and indoors IP65 – outdoors and indoors
Mounting Included bracket Included bracket Included bracket Included bracket Included bracket

(1) Option available in some countries. For more information: https://www.solaredge.com/sites/default/files/se_inverters_supported_countries.pdf

(2) 49990 in the United Kingdom

(3) If an external RCD is required, its tripping value must be ≥ 200 mA for SE50K/SE66.6K; ≥ 300 mA for SE90K, SE100K

(4) If allowed by local regulations

(5) For specifications regarding additional communication options, please visit https://www.solaredge.com/products/communication or the Resource Library at: https://www.solaredge.com/downloads# to download the relevant datasheet

(6) All standards and certifications are available for download in the “Certificates” section of the Resource Library: https://www.solaredge.com/downloads#/

(7) DC input is available with MC4 connectors or grommets under the inverter part number. For more information, please contact SolarEdge

(8) Only MC4 connectors manufactured by Staubli are approved for use

(9) Power derating – for specifications, see https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf

Official distribution