Inverter SOLIS S6-EH3P10K-H-EU
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 3 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
Wi-Fi | Optional |
RS485 | Yes |
CAN | Yes |
LAN | Optional |
SPD Type II |
Gross
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Hybrid device | |
MPPT | 3 |
AFCI | Optional |
Warranty | |
Net width | |
Net depth | |
Net height | |
Wi-Fi | Optional |
RS485 | Yes |
CAN | Yes |
LAN | Optional |
SPD Type II |
Three-Phase, High-Voltage Solis S6-EH3P(3-10)K-H-EU Inverters for Energy Storage
The Solis S6-EH3P(3-10)K-H-EU inverter series represents advanced, three-phase, high-voltage hybrid solutions designed for efficient energy storage in photovoltaic systems. They combine high efficiency, intelligent energy management features, and wide compatibility, making them a versatile choice for modern installations. With integrated multiple MPPT trackers and UPS functionality, they ensure optimal utilization of solar energy and reliable power supply.
Key Features of Solis S6-EH3P(3-10)K-H-EU Inverters:
- Integrated 2/3/4 MPPT: Allow for flexible design of photovoltaic systems with panels oriented in different directions, maximizing energy yield.
- High Charging/Discharging Power: Offer best-in-class maximum charging/discharging ratings of up to 50 A / 10 kW (depending on the model).
- Automatic UPS Switching: Ensure uninterrupted power supply with a UPS function that has a switching time of less than 10 ms.
- Support for Unbalanced Loads: Capable of handling unbalanced and half-wave loads on both the grid and backup ports.
- Wide Compatibility and Easy Installation: Compatible with many brands of lithium batteries (Li-ion), while pre-wired battery, meter, and CAN connections reduce installation time.
- Advanced Protection and Performance: Provide enhanced battery protection and operational features that extend battery life, with a maximum inverter efficiency of up to 97.9%.
Who is it Suitable For?
The Solis S6-EH3P(3-10)K-H-EU inverters are an excellent choice for homeowners and small businesses looking to maximize their solar energy self-consumption and achieve energy independence. With UPS functionality, they are particularly well-suited for locations requiring continuous power supply. Their flexibility, stemming from support for multiple MPPTs and compatibility with various batteries, makes them appropriate for diverse photovoltaic system configurations, including those with panels oriented in different directions or plans for future expansion.
Parameter | S6-EH3P3K-H-EU | S6-EH3P4K-H-EU | S6-EH3P5K-H-EU | S6-EH3P6K-H-EU | S6-EH3P8K-H-EU | S6-EH3P10K-H-EU |
---|---|---|---|---|---|---|
DC Connection (PV Side) | ||||||
Recommended maximum PV array size (kW) | 6 | 8 | 10 | 12 | 16 | 20 |
Max. usable input power PV (kW) | 4.8 | 6.4 | 8 | 9.6 | 12.8 | 16 |
Max. input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated voltage (V) | 600 | 600 | 600 | 600 | 600 | 600 |
Startup voltage (V) | 160 | 160 | 160 | 160 | 160 | 160 |
MPPT voltage range (V) | 200-850 | 200-850 | 200-850 | 200-850 | 200-850 | 200-850 |
Max. input current (A) | 16 A/16 A | 16 A/16 A | 16 A/16 A/16 A | 16 A/16 A/16 A | 16 A/16A/16A/16 A | 16 A/16A/16A/16 A |
Max. short circuit current (A) | 24 A/24 A | 24 A/24 A | 24 A/24 A/24 A | 24 A/24 A/24 A | 24 A/24 A/24 A/24 A | 24 A/24 A/24 A/24 A |
Number of MPPTs/Max. number of series inputs | 2/2 | 2/2 | 3/3 | 3/3 | 4/4 | 4/4 |
Battery | ||||||
Battery type | Li-ion | Li-ion | Li-ion | Li-ion | Li-ion | Li-ion |
Battery voltage range (V) | 120-600 | 120-600 | 120-600 | 120-600 | 120-600 | 120-600 |
Max. charging/discharging power (kW) | 3 | 4 | 5 | 6 | 8 | 10 |
Max. charging/discharging current (A) | 25 | 25 | 50 | 50 | 50 | 50 |
Communication | CAN/RS485 | CAN/RS485 | CAN/RS485 | CAN/RS485 | CAN/RS485 | CAN/RS485 |
AC Output Socket (Grid Side) | ||||||
Rated output power (kW) | 3 | 4 | 5 | 6 | 8 | 10 |
Max. apparent output power (kVA) | 3 | 4 | 5 | 6 | 8 | 10 |
Rated grid voltage (V) | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V |
Rated grid frequency (Hz) | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
Rated output current (A) | 4.6 A/4.3 A | 6.1 A/5.8 A | 7.6 A/7.2 A | 9.1 A/8.7 A | 12.2 A/11.5 A | 15.2 A/14.4 A |
Max. output current (A) | 4.6 A/4.3 A | 6.1 A/5.8 A | 7.6 A/7.2 A | 9.1 A/8.7 A | 12.2 A/11.5 A | 15.2 A/14.4 A |
Power factor | > 0.99 (-0.8 to 0.8) | > 0.99 (-0.8 to 0.8) | > 0.99 (-0.8 to 0.8) | > 0.99 (-0.8 to 0.8) | > 0.99 (-0.8 to 0.8) | > 0.99 (-0.8 to 0.8) |
Total harmonic distortion of current (%) | <3% | <3% | <3% | <3% | <3% | <3% |
DC Output Socket (Grid Side) | ||||||
Max. input power (kW) | 4.5 | 6 | 7.5 | 9 | 12 | 15 |
Rated input current (A) | 6.8 | 9.1 | 11.4 | 13.8 | 18.2 | 22.8 |
Rated input voltage (V) | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V |
Rated input frequency (Hz) | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
AC Output Socket (Backup Status) | ||||||
Rated output power (kW) | 3 | 4 | 5 | 6 | 8 | 10 |
Peak apparent output power (kVA, 60 sec) | 4.8 | 6.4 | 8 | 9.6 | 12.8 | 16 |
Backup switching time (ms) | <10 | <10 | <10 | <10 | <10 | <10 |
Rated output voltage (V) | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V | 3/N/PE, 380 V / 400 V |
Rated frequency (Hz) | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
Rated output current (A) | 4.6 A/4.3 A | 6.1 A/5.8 A | 7.6 A/7.2 A | 9.1 A/8.7 A | 12.2 A/11.5 A | 15.2 A/14.4 A |
Total harmonic distortion of voltage (@linear load) (%) | <2% | <2% | <2% | <2% | <2% | <2% |
Efficiency | ||||||
Max. efficiency (%) | 95.5% | 96.0% | 96.5% | 97.0% | 97.5% | 97.9% |
EU Efficiency Standard (%) | 95.5% | 96.0% | 96.8% | 97.1% | 97.4% | 97.5% |
BAT charged by max. PV efficiency (%) | 96.0% | 96.6% | 98.4% | 98.5% | 98.2% | 98.3% |
BAT charged/discharged to max. AC efficiency (%) | 97.0% | 97.3% | 97.3% | 97.3% | 97.5% | 97.5% |
MPPT efficiency (%) | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% |
Protection | ||||||
Anti-islanding protection | Yes | Yes | Yes | Yes | Yes | Yes |
Output overcurrent protection | Yes | Yes | Yes | Yes | Yes | Yes |
Short circuit protection | Yes | Yes | Yes | Yes | Yes | Yes |
Integrated AFCI 2.0 | Optional | Optional | Optional | Optional | Optional | Optional |
Integrated DC disconnect switch | Yes | Yes | Yes | Yes | Yes | Yes |
DC reverse polarity protection | Yes | Yes | Yes | Yes | Yes | Yes |
PV surge protection | Yes | Yes | Yes | Yes | Yes | Yes |
Polarity protection | Yes | Yes | Yes | Yes | Yes | Yes |
General Data | ||||||
Dimensions (W*H*D) (mm) | 600*500*210 | 600*500*210 | 600*500*210 | 600*500*210 | 600*500*230 | 600*500*230 |
Weight (kg) | 26.4 | 26.4 | 27.6 | 27.6 | 30.2 | 30.2 |
Topology | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless | Transformerless |
Self-consumption (night) (W) | <25 | <25 | <25 | <25 | <25 | <25 |
Operating ambient temperature range (°C) | -25 ~ +60°C | -25 ~ +60°C | -25 ~ +60°C | -25 ~ +60°C | -25 ~ +60°C | -25 ~ +60°C |
Relative humidity (%) | 0-95% | 0-95% | 0-95% | 0-95% | 0-95% | 0-95% |
Protection degree | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
Cooling concept | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection | Natural convection |
Maximum operating height (m above sea level) | 4000 | 4000 | 4000 | 4000 | 4000 | 4000 |
Grid connection standard | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | G98 or G99, VDE-AR-N 4105/VDE V 0124, EN 50549-1, VDE 0126 / UTE C 15/VFR:2019, RD 1699/RD 244 / UNE 206006/UNE 206007-1, CEI 0-21, C10/11, NRS 097-2-1, TOR, EIFS 2018.2, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA |
Safety standard / EMC | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 | IEC/EN 62109-1/-2, IEC/EN 61000-6-1/-3 |
Features | ||||||
PV connection | MC4 connector | MC4 connector | MC4 connector | MC4 connector | MC4 connector | MC4 connector |
Battery connection | Quick connector | Quick connector | Quick connector | Quick connector | Quick connector | Quick connector |
AC connection | Quick connector | Quick connector | Quick connector | Quick connector | Quick connector | Quick connector |
Display | LED + Bluetooth + APP | LED + Bluetooth + APP | LED + Bluetooth + APP | LED + Bluetooth + APP | LED + Bluetooth + APP | LED + Bluetooth + APP |
Communication | CAN, RS485, Optional: Wi-Fi, Cellular, LAN | CAN, RS485, Optional: Wi-Fi, Cellular, LAN | CAN, RS485, Optional: Wi-Fi, Cellular, LAN | CAN, RS485, Optional: Wi-Fi, Cellular, LAN | CAN, RS485, Optional: Wi-Fi, Cellular, LAN | CAN, RS485, Optional: Wi-Fi, Cellular, LAN |